BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//NDNR - Naturopathic Doctor News and Review - ECPv6.17.5//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-WR-CALNAME:NDNR - Naturopathic Doctor News and Review
X-ORIGINAL-URL:https://ndnr.com
X-WR-CALDESC:Events for NDNR - Naturopathic Doctor News and Review
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Denver
BEGIN:DAYLIGHT
TZOFFSETFROM:-0700
TZOFFSETTO:-0600
TZNAME:MDT
DTSTART:20170312T090000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0600
TZOFFSETTO:-0700
TZNAME:MST
DTSTART:20171105T080000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0700
TZOFFSETTO:-0600
TZNAME:MDT
DTSTART:20180311T090000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0600
TZOFFSETTO:-0700
TZNAME:MST
DTSTART:20181104T080000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0700
TZOFFSETTO:-0600
TZNAME:MDT
DTSTART:20190310T090000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0600
TZOFFSETTO:-0700
TZNAME:MST
DTSTART:20191103T080000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20180215
DTEND;VALUE=DATE:20180217
DTSTAMP:20171213T222419Z
CREATED:20171213T222419Z
LAST-MODIFIED:20171213T222419Z
UID:27884-1518652800-1518825599@ndnr.com
SUMMARY:Risk Management Education Course | Medical Devices Industry 2018
DESCRIPTION:Event: Risk Management Education Course | Medical Devices Industry 2018 \nVenue: Courtyard By Marriott Dallas DFW Airport North/Irving\n4949 Regent Blvd\nDallas\, TX\, 75063 \nCourse “Risk Management in Medical Devices Industry” has been pre-approved by RAPS as eligible for up to 12 credits towards a participant’s RAC recertification upon full completion. \nOverview: \nGaps\, incorrect or incomplete implementation of software can delay or make the certification/approval of medical products impossible. Most activities cannot be retroactively performed since they are closely linked into the development life-cycle. Diligent\, complete and correct implementation of risk management from the start of product development is therefore imperative. This course will introduce all necessary steps to design\, implement and test critical medical device software in a regulatory compliant environment. Software risk management has to be embedded into the bigger scope of overall risk management. Therefore this course will additionally address the system level risk management and the resulting interfaces to software.\nTo comprehensively summarize all risk related activities and to demonstrate the safe properties of a device the ‘Safety Case’ or ‘Assurance Case’ document is a well-established method to collect all safety related information together in one place. This documentation will most likely become mandatory for all devices (currently only required for FDA infusion pump submissions). This course will introduce the basic concepts and content of safety assurance cases and will illustrate the usefulness for internal and external review of safety related information. \nWho will benefit: \nThe course will introduce the main elements of risk management with emphasis on software issues and the application of risk management principles and requirements to the medical device development cycle. Risk management has become the method of choice to ensure an effective and safety oriented device development. International consensus\, reflected in globally applicable standard requirements\, has led to risk management being a mandatory component of almost any activity in the medical device industry.\nThe course will emphasize the implementation of risk management into the development and maintenance process. It will use real-life examples and proven tips and tricks to make the application of risk management a practical and beneficial undertaking. This seminar will address the system level issues of risk management as well as the increasingly important software related issues of critical systems. It will help to comply with regulatory requirements with minimized overhead and resource burden. To make the combines effort to design\, implement and verify a safe device transparent the concept of an assurance case will be introduced.\nThe course is mainly based on international consensus requirements such as ISO14971 and IEC62304. \nFollowing personnel will benefit from the course:\n• Senior Quality Managers\n• Quality Professionals\n• Regulatory Professionals\n• Compliance Professionals\n• Project Managers\n• Design Engineers\n• Software Engineers\n• Process Owners\n• Quality Engineers\n• Quality Auditors\n• Medical Affairs\n• Legal Professionals \nAgenda: \nDay 1 Schedule \nLecture 1:\nIntroduction into Risk Management and Quality System Integration\n• Why risk management?\no Historical perspective\no International regulatory / statutory requirements\n• Risk Management Lifecycle and stakeholders\no Over-reaching concept\no Integration into ISO13485\no Lifecycle steps\n• Risk Management Benefits\no Liability issues\no Streamlining product development\no Improving product safety and quality\n• How to Implement Risk Management into ISO13485\no SOP framework\no Planning and execution\no Monitoring and control\n• Tips and tricks\nLecture 2:\nRisk Management to ISO 14971:2012\n• Risk Management Planning\n• Risk Management Life Cycle\n• Hazard Identification\no Hazard Domains\no Hazard Latency Issues\no Risk Rating Methods\n• Initial (unmitigated) Risk Assessment\n• Mitigation Strategies and Priorities\n• Mitigation Architectures\no Alarm Systems as Mitigations\no Risk Control Bundles\n• Post Mitigation Risk\n• Residual Risk\no Safety Integrity Levels\n• European special requirements (Z-Annexes)\n• Safety Requirements\n• Hazard Mitigation Traceability\n• Verification Planning\n• Architectures\, Redundancy and Diversity\n• Failure Mode and Effect Analysis\n• Tips and Tricks\n• Q&A \nDay 2 Schedule \nLecture 1:\nSoftware Risk Management (IEC62304 / FDA software reviewers’ guidance):\n• Critical Software Issues\n• Software Hazard Mitigation Strategies\n• Software Item\, Unit and System Definition\n• Software Failures as Hazard Sources\n• Software Requirements and Design Specification\n• Software Tools and Development Environment\n• Software Unit and Integration Testing\n• Real-Time System Challenges\n• Software Verification and Validation\n• Mitigation Traceability and Effectiveness\n• Software Maintenance and Configuration Control\n• Software Risk Management Process integration into ISO14971\n• Legacy Software issues\n• FDA documentation requirements\n• Upcoming changes in IEC62304:2014\n• Tips and Tricks\n• Q&A\nLecture 2:\nSafety / Assurance case\n• Safety classes\no Basic Safety / Environment\no Essential performance\n• Documentation of Basic Safety\no Electrical Safety\no Mechanical Safety\no EMC / RFI safety\no Safety margins\n• Documentation of essential performance\no What is essential performance?\no Device architectures and mitigation allocation\no Device specific mitigations\no Software mitigations\n• External safety\no User intervention and alarms\no Organizational measures\no Levels of protection concept\n• Verification of safety properties\no Type testing\no Sample testing\no Software verification testing\no Inspections\no Analyses\n• Assurance case vs. Risk Management Report\no General safety and hazard avoidance\no Device / application specific issues\n• Tips and Tricks\n• Q&A \nSpeaker\nMarkus Weber\nPrincipal Consultant\, System Safety Inc. \nMarkus Weber\, Principal Consultant with System Safety\, Inc.\, specializes in safety engineering and risk management for critical medical devices. He graduated from Ruhr University in Bochum\, Germany with a MS in Electrical Engineering. Before founding System Safety\, Inc.\, he was a software safety engineer for the German approval agency\, TUV. Since 1991\, Mr. Weber has been a leading consultant to the medical device industry on safety and regulatory compliance issues\, specifically for active and software-controlled devices. In conjunction with the FDA\, he has published works on risk management issues and software-related risk mitigations. Mr. Weber has helped multiple companies\, from startups to Fortune 500 firms. \nLocation: Dallas\, TX Date: February 15th & 16th\, 2018 and Time: 9:00 AM to 6:00 PM\nVenue: Courtyard By Marriott Dallas DFW Airport North/Irving 4949 Regent Blvd Irving\, TX\, 75063 United States \nPrice: Register now and save $200. (Early Bird)\nPrice: $1\,295.00 (Seminar Fee for One Delegate)\nUntil January 15\, Early Bird Price: $1\,295.00 From January 16 to February 13\, Regular Price: $1\,495.00\nRegister for 5 attendees Price: $3\,885.00 $6\,475.00 You Save: $2\,590.00 (40%)*\nRegister for 10 attendees Price: $7\,122.00 $12\,950.00 You Save: $5\,828.00 (45%)* \nSponsorship Program benefits for “Quality Assurance Auditing for FDA Regulated Industry” seminar\nAt this seminar\, world-renowned FDA Regulated Industry subject matter experts interact with CXO’s of various designations. Executives who carry vast experience about FDA Regulated Industry and Experts get down to discussing industry-related best practices\, regulatory updates\, changes in technologies\, and much more relating to FDA Regulated Industry.\nAs a sponsor of these seminars\, you get the opportunity to have your product and company reach out to C-Level executives in FDA Regulatory -related industries and become known among these elite executives and subject matter experts. Apart from being seen prominently at these globally held seminars\, you also get talked about frequently in our correspondences with our experts and these participants.\nFor More Information- https://www.globalcompliancepanel.com/control/sponsorship
URL:https://ndnr.com/event/risk-management-education-course-medical-devices-industry-2018/
CATEGORIES:Course
END:VEVENT
END:VCALENDAR